Description

330904-00-10-70-01-05 Probe Overview

Key Performance Metrics

  • Minimum Detectable Amplitude: 50 µVrms
  • Supply Current: 10 mA typical at 24 Vdc
  • Noise Floor: 0.01 mm peak-to-peak
  • Cross-Axis Sensitivity: ≤0.5 %
  • Bandwidth: 0–12 kHz (±3 dB)
  • Cable Weight: 40 g/m
  • Resolution: 0.001 mm

Suffix Breakdown & Ordering

Base Model: 330904
-00 = 0 mm unthreaded tip, -10 = 100 mm case, -70 = 7.0 m cable, -01 = ClickLoc connector with protector & standard cable, -05 = ATEX/IECEx/CE approvals
Operating Range: –52 °C to +177 °C
Warranty: 1 year

Download PDF file here:3300 XL NSv Proximity Transducer System Datasheet – 147385

Additional information

Weight0.15 kg
Dimensions24 × 24 × 3 cm